3.2. The details of the parameter setting
3.2.1. Device name (c081-c096)
This option module can set the "Device name" of 16 characters.
(Device name (c081-c096) is 1 character within one parameter.)
The device name is required if the option module uses DHCP to obtain its IP Address.
Please set the setting of the device name according to the following rules.
1. The parameter is displayed by the hexadecimal number.
2. One parameter shows an ASCII character.
3. The relation between the device name and the parameter is as follows.
Example for Device Name =’VFMB1-4007PL’
Chars No. Parameter Character (Ex.) ASCII (Ex.)
1 c081 ‘V’ 56H
2 c082 ‘F’ 46H
3 c083 ‘M’ 4DH
4 c084 ‘B’ 42H
5 c085 ‘1’ 31H
6 c086 ‘-‘ 2DH
7 c087 ‘4’ 34H
8 c088 ‘0’ 30H
9 c089 ‘0’ 30H
10 c090 ‘7’ 37H
11 c091 ‘P’ 50H
12 c092 ‘L’ 4CH
13 c093 - -
14 c094 - -
15 c095 - -
16 c096 - -